Thoracic surgery
HOME > 상품정보 > Thoracic surgery
Oxygenator
CAPIOX® RX
  • Housing material Polycarbonate ​ ​
  • Fiber material Microporous polypropylene ​ ​
  • Heat exchanger material Stainless steel ​ ​
Product Details

  

Description

Oxygenator

Balanced Performance

  • Low priming volume, high gas exchange and low pressure drop are optimally balanced for superb performance.
  • Hollow fibers manufactured exclusively by Terumo using a patented technology with total quality management from raw materials to finished product.
  • Woven fiber bundle ensures consistent and high-performance gas exchange.
  • Choice of blood outlet port configurations for easy access and increased circuit flexibility.
  • Top-to-bottom blood flow path and air purge line provide excellent air removal capability.
  • No DEHP used in PVC tubing.

 


Hardshell Reservoir

Full Featured

  • Elongated shape provides a stable blood flow path and enhanced visibility at all levels from all angles.
  • Rotating venous inlet improves set-up flexibility.
  • No DEHP used in PVC tubing.
  • Connecting mount increases flexibility in circuit set-up and oxygenator rotation.
  • Funnel-shaped cardiotomy filter improves breakthrough and residual volumes.
  • Positive pressure relief value for additional safety.

 

 

Characteristics

  • Terumo’s exclusive hollow fiber
  • High flow with very low priming volume
  • Superior O2 transfer performance
  • Outstandingly low pressure drop

 

 

 

General specifications

Oxygenator 

 

 

 Oxygenator

RX15 R30 reservoir

RX15 R40 reservoir

RX25

 Housing material

Polycarbonate ​ ​

 Fiber material

Microporous polypropylene ​ ​

 Heat exchanger material

Stainless steel ​ ​

 Fibers: Approx. surface area

1.5 m²

1.5 m²

2.5 m²

 Heat exchanger: Approx. surface area

0.14 m²

0.14 m²

0.2 m²

 Blood flow range

0.5 - 4.0 L/min

0.5 - 5.0 L/min

0.5 - 7.0 L/min

 Priming Volume (static)

135 mL

135 mL

250 mL

 Blood inlet port (from pump)

3/8" (9.5 mm) ​ ​

 Blood outlet port

3/8" (9.5 mm) ​ ​

 Cardioplegia port

1/4" (6.4 mm) ​ ​

 Gas inlet port

1/4" (6.4 mm) ​ ​

 Gas outlet port

1/4" (6.4 mm) ​ ​

 Water ports

1/2" (12.7 mm) Hansen quick connect fittings ​ ​

 Maximum pressure Blood inlet

133 kPa (1.000 mmHg) ​ ​

 Maximum pressure Water inlet

196 kPa (2 kgf/cm²)(28.5 psi) ​ ​

 


Hardshell reservoir 

 

 Hardshell Reservoir

RX15 R30 reservoir

RX15 R40 reservoir

RX25

 Housing material

Polycarbonate ​ ​

 Venous filter materials

Polyester screen type ​ ​

 Cardiotomy filter material

Polyester depth type ​ ​

 Defoamer material

Polyurethane foam ​ ​

 Blood flow range: Venous

0.5 – 4.0 L/min

0.5 - 5.0 L/min

0.5 - 7.0 L/min

 Blood flow range: Cardiotomy inlet

4.0 L/min

5.0 L/min

5.0 L/min

 Blood flow range: Combined flow

4.0 L/min

5.0 L/min

7.0 L/min

 Blood storage capacity

3,000 mL

4,000 mL

4,000 mL

 Minimum operating volume

70 mL

200 mL

200 mL

 Venous blood inlet port (rotatable) 

3/8" (9.5 mm)

1/2" (12.7 mm) ​

 Blood outlet port (to pump) 

3/8" (9.5 mm)

3/8" (9.5 mm) ​

 Suction ports (rotatable)

Six: 1/4" (6.4 mm) ​ ​

 Vertical port (to CR filter)

3/8" (9.5 mm)     ​ ​

 Quick prime port

1/4" (6.4 mm)     ​ ​

 Vent port

1/4" (6.4 mm)     ​ ​

 Auxiliary port

1/4" – 3/8" (6.4 mm – 9.5 mm)     ​ ​

 Luer ports

Three filtered luer locks to cardiotomy filter, one non-filtered luer lock, two luer locks on venous inlet ​ ​

 Maximum sustainable negative pressure in reservoir

-20.0 kPa (-150 mmHg)     ​ ​